This manual details the Fluke 179’s operation, safety, and specifications. It covers features like frequency counting, data hold, and temperature measurement,
ensuring accurate readings and reliable performance for professionals.

The Fluke 179 is a professional-grade, true-RMS multimeter designed for electrical troubleshooting and precision measurement. This robust tool conforms to IEC 1010-1 safety standards, offering CAT IV 600V safety ratings. It’s ideal for field service engineers, electricians, and technicians needing reliable performance.
The manual guides users through its capabilities.
The Fluke 179 boasts true-RMS accuracy for AC voltage and current measurements, ensuring precise readings even on non-sinusoidal waveforms. Key benefits include auto and manual ranging, frequency counter functionality, temperature measurement in Celsius and Fahrenheit, and Min/Max recording.
It offers data hold for convenient analysis.
To ensure user safety, always adhere to IEC 1010-1 standards. Avoid applying voltage exceeding the meter’s CAT IV 600V rating. Inspect leads for damage before use. Never work on energized circuits without proper training.
Replace fuses only with specified types, and disconnect all power before maintenance.
The Fluke 179 features a large, easy-to-read digital display. It shows the measured value, units, and various icons indicating functions like data hold, low battery, or continuity.
The display also includes a bar graph for analog representation and range indication for clear visualization of measurements.
The Fluke 179 utilizes intuitive button controls for seamless operation. Buttons include power, range, hold, min/max, and a selector knob for function choice.
The AutoHOLD function automatically captures stable readings, while the HOLD button freezes the current display value for convenient recording.
The Fluke 179 offers versatile measurement modes for diverse applications. It accurately measures AC/DC voltage, AC/DC current, resistance, and continuity.
Additionally, it features a diode test function and temperature measurement in both Celsius and Fahrenheit, providing comprehensive electrical testing capabilities.
The Fluke 179 measures AC voltage up to 600.0 mV with 0.1 mV resolution. Accuracy is specified as ± (1.0% of reading + 3 digits) for optimal results.
Ensure proper fuse protection is utilized when measuring, and always adhere to the CAT IV 600V safety rating for reliable and safe operation.
The Fluke 179 accurately measures DC voltage, crucial for various electrical applications. While specific ranges aren’t detailed in the provided snippets, the meter’s overall accuracy specifications apply.
Prioritize safety by understanding input impedance and utilizing appropriate test leads for precise and dependable DC voltage readings.
The Fluke 179 measures both AC and DC current, essential for comprehensive electrical analysis. Fuse protection is vital during current measurements; the manual details fuse specifications for 10A and 400mA ranges.
Always observe safety precautions and utilize the correct input terminals for accurate readings.
The Fluke 179 accurately measures resistance, crucial for diagnosing circuit issues and component health. Ensure the circuit is de-energized before testing. The meter provides a clear display of resistance values, aiding in quick identification of faulty components or breaks in the circuit path.

Utilize the Fluke 179’s continuity function to verify electrical connections. A low resistance path triggers an audible beep, confirming circuit integrity. This is vital for troubleshooting wiring, switches, and fuses. Always de-energize the circuit before testing for continuity to prevent damage to the meter.
The Fluke 179’s diode test function assesses diode functionality by applying a forward voltage. A healthy diode exhibits a forward voltage drop (typically 0.5V to 0.8V), while an open or shorted diode indicates failure. Ensure the circuit is de-energized before performing this test for accurate results.


The Fluke 179 accurately measures temperature using a K-type thermocouple probe (sold separately). Users can toggle between Celsius and Fahrenheit scales for convenient readings. Ensure proper probe contact for precise measurements, and be mindful of the probe’s temperature range specifications for optimal performance.
The Fluke 179 features a built-in frequency counter for measuring signal frequencies. It offers a specified sensitivity range for accurate detection. Users can measure frequency by selecting the frequency mode and connecting the signal to the appropriate input terminals, ensuring proper signal conditioning.
The Fluke 179 simplifies readings with Data Hold, freezing the displayed value for later reference. Auto Hold automatically captures stable readings, ideal for fluctuating signals. These features enhance usability, allowing technicians to record measurements conveniently, even in hard-to-reach or visually obstructed locations.
The Fluke 179 efficiently captures fluctuating measurements using its Min/Max recording function; This feature automatically records the minimum and maximum values encountered over a specified period. Technicians can quickly identify peak and low points, aiding in troubleshooting and comprehensive analysis of electrical signals and parameters.

The Fluke 179 boasts comprehensive specifications for precise measurements. Accuracy is ±0.1% for DC Voltage, with input impedance of 10 MΩ. Fuse protection is included, safeguarding against overcurrents. It conforms to IEC 1010-1 safety standards, ensuring reliable and safe operation for various electrical testing applications.
The Fluke 179 delivers accuracy of ±0.09% for DC Voltage and ±1.0% for AC Voltage. Resistance accuracy is ±0.2%, ensuring precise readings. Current measurements offer similar precision. These specifications, expressed as a percentage of reading, guarantee reliable results for professional electrical measurements and troubleshooting.
The Fluke 179 boasts a high input impedance of 10 MΩ for DC voltage measurements, minimizing circuit loading and ensuring accurate readings. For AC voltage, the impedance is also 10 MΩ. This high impedance prevents significant disturbance to the measured circuit, crucial for sensitive electronic applications.
The Fluke 179 utilizes fuse protection for current measurement circuits, safeguarding the meter from damage. It features a 400mA, 600V fast-blow fuse for the mA input and a 10A, 600V fast-blow fuse for the 10A input. Always replace fuses with the specified type to maintain safety and accuracy.
If the meter displays “OL”, it indicates an overload condition; reduce the range or input signal. A blank display suggests a dead battery – replace it immediately. Inaccurate readings may stem from incorrect range selection or damaged test leads. Ensure proper fuse integrity for current measurements.
The Fluke 179 requires 9V alkaline batteries for operation. Replace batteries when the low battery indicator appears on the display. Regularly clean the meter’s exterior with a damp cloth. Avoid harsh chemicals or abrasives. Inspect test leads for damage and replace as needed to maintain accuracy.
A supplement users manual is available for download online as a PDF or text file. This document includes updates and changes to the original manual, such as frequency counter sensitivity details. Search “Fluke 179 Supplement Users Manual” to find and review the latest information for your meter.
This guide provides detailed instructions for the Fluke 179, covering its features, safety precautions, and accurate measurement techniques for professional use.
The Fluke 179 is a professional-grade digital multimeter designed for electrical troubleshooting and precision measurement. This robust tool offers True-RMS accuracy and a comprehensive set of functions, including voltage, current, resistance, continuity, diode, frequency, and temperature. It’s built for reliability and safety, conforming to IEC 1010-1 standards, making it ideal for field service and demanding applications.
The Fluke 179 boasts True-RMS accuracy for precise AC measurements, alongside auto and manual ranging for versatile use. Key benefits include a large, easy-to-read display, Min/Max recording, and data hold functions. Its CAT IV 600V safety rating ensures user protection, while temperature measurement in Celsius and Fahrenheit expands its utility.
Always adhere to IEC 1010-1 safety standards when using the Fluke 179. Avoid measurements on ungrounded systems. Inspect leads for damage before each use, and never exceed the meter’s CAT IV 600V rating. Disconnect circuits before measuring resistance or diodes. Exercise caution with voltages above 30V.
The Fluke 179 features a large, easy-to-read digital display. It shows the measured value, units, and various icons indicating functions like data hold, auto-hold, low battery, and input impedance; The display also includes a bar graph for analog representation of measurements.
The Fluke 179 utilizes intuitive button controls for seamless operation. Key buttons include Range (manual/auto), Hold (data retention), Min/Max (recording extremes), and Auto Hold (automatic stabilization). The power button activates the meter, while the selector knob chooses measurement modes.
The Fluke 179 offers versatile measurement capabilities. It accurately measures AC/DC Voltage, AC/DC Current, Resistance, and performs Continuity, Diode, and Temperature tests. The integrated frequency counter provides precise frequency readings, while True RMS ensures accurate AC signal measurements.
To measure AC Voltage, select the appropriate voltage range on the rotary dial. Connect the test leads; black to COM and red to V. The 179 measures up to 600V AC with 1mV resolution, offering 1.0% accuracy. Ensure CAT IV safety ratings are observed for higher voltage applications.
For DC Voltage measurements, turn the dial to the desired DC voltage range. Connect the black test lead to COM and the red lead to V. The Fluke 179 offers resolution down to 0.1mV, with accuracy of 1.0% for readings up to 600V DC, ensuring precise results.
To measure current, use the appropriate fuse-protected input jacks. Select the AC or DC current range using the rotary dial. The Fluke 179 handles up to 10A, with a 400mA fused range for sensitive measurements, providing safe and accurate current readings in various applications.

Resistance is measured by selecting the Ω range on the rotary dial. Ensure the circuit is de-energized before measuring resistance. The Fluke 179 provides accurate resistance readings, crucial for verifying component values and circuit integrity. It’s a fundamental diagnostic function for electrical troubleshooting.
Continuity testing utilizes the audible beep function to indicate a short circuit. Select the continuity mode (diode symbol) and touch the probes to the circuit points. A low resistance path triggers the beep, confirming connection. This is vital for checking wires, fuses, and switch contacts quickly.
The diode test function assesses diode functionality by applying a forward voltage. A healthy diode exhibits a forward voltage drop (typically 0.5V to 0.8V), while an open diode shows “OL” and a shorted diode reads near zero. This test verifies semiconductor integrity within circuits.

The Fluke 179 accurately measures temperature using a K-type thermocouple probe (sold separately). Users can toggle between Celsius and Fahrenheit scales for convenient readings. This function is ideal for HVAC, automotive, and industrial applications, providing precise temperature data for troubleshooting and analysis.
The Fluke 179 features a built-in frequency counter for measuring the frequency of electrical signals. It offers sensitivity within a specific input range, as detailed in the supplement manual. This function is crucial for analyzing AC power, diagnosing electronic circuits, and verifying signal integrity.
The Fluke 179 simplifies readings with Data Hold, freezing the displayed value for later review. Auto Hold automatically captures stable readings, ideal for fluctuating signals. These features enhance usability, especially in challenging environments, ensuring accurate data recording without constant visual monitoring of the display.
The Fluke 179 efficiently captures fluctuating measurements using its Min/Max recording function. This feature automatically records the minimum and maximum values encountered over a period, providing a comprehensive overview of signal variations. It’s invaluable for troubleshooting and identifying intermittent issues quickly and reliably.
The Fluke 179 boasts precise accuracy, with specifications varying by function and range. AC Voltage accuracy is ±1.0% of reading, while DC Voltage is also ±1.0%. Input impedance is 10 MΩ. Fuse protection is included for current measurements, ensuring safe and reliable operation across diverse applications.
The Fluke 179’s accuracy is specified as a percentage of reading plus counts. For AC Volts, it’s ±1.0% with 600.0 mV resolution. DC Volts also achieve ±1.0% accuracy. Resistance measurements offer similar precision. These specifications guarantee reliable and consistent results for professional electrical testing.
The Fluke 179 boasts high input impedance, crucial for minimizing circuit loading. This ensures accurate measurements without significantly affecting the tested circuit’s behavior. While specific values aren’t detailed, the design prioritizes minimal impact. High impedance is vital for voltage measurements, especially in high-resistance circuits.

The Fluke 179 utilizes fuse protection for safety and instrument preservation. It features separate fuses for different current ranges – typically a 400mA and a 10A fuse. Always replace fuses with the specified type and rating to avoid damage or inaccurate readings. Fuse access is clearly indicated on the meter’s front panel.

If the Fluke 179 displays unexpected readings, check the battery first. A low battery can cause inaccurate measurements. Verify probe connections and ensure proper function. Inspect the fuses for any breaks. If issues persist, consult the supplement user manual for detailed troubleshooting steps and potential solutions.
The Fluke 179 requires regular battery checks for optimal performance. Replace with 9V alkaline batteries when the low battery indicator appears. Ensure proper polarity during installation. Clean the battery contacts periodically to prevent corrosion. Store the meter in a dry, clean environment when not in use for longevity.
A supplemental user manual is available online as a PDF or text file. It includes updates and changes, such as frequency counter sensitivity details. Download it from Fluke’s official website or related online resources. Refer to this supplement for the latest information regarding your 179 meter’s functionality.
You must be logged in to post a comment.